Fast and simple installation in all possible ways.
Uniclic flooring installation instructions.
The uniclic locking system enables you to engage the flooring panels via two methods angling and snapping.
Click the panels together on the short side and drill a hole in the center of the joint between the two panels.
Installation instructions uniclic is a revolutionary system for installing laminate floors without using glue.
Take a drill bit with the same diameter as the pipe plus 20mm 3 4 for the expansion.
This fact makes uniclic one of the easiest locking mechanisms for do it yourself flooring installations and the favorite of onflooring.
It is necessary that the crawl space under the plank floor be sufficiently ventilated.
Unilin invented the uniclic patented joint locking system.
Download laminate plank installation tile installation guides.
Installing sheet vinyl consult your flooring retailer about the recommended method of installing your mohawk sheet vinyl.
Uniclic the traditional glueless locking technology.
Locking profile for both sides of the panels.
Position the panel to be installed at an angle of 20 to 30 to the panel already installed.
Install the uniclic panels crosswise to the direction of the existing sub floor.
To confirm you have the most recent installation instructions please contact technical services.
Uniclic is unique because you can install the planks in two different ways.
The substrate temperature must be between 65 f and 85ºf 18ºc and 29ºc at the time of installation un opened cartons of flooring should be stored flat and neatly stacked in the climate controlled installation area for a minimum of 48 hours prior to installation to allow product to acclimate.
Move the plank gently up and down while applying forward pressure.
With the patented uniclic multifit vinyl planks can be installed horizontally vertically or at an angle so installation is easy and saves you both money and time.
We also have flushmount and uniclic installation videos.
Angling and snapping installation methods.
General uniclic angle is a revolutionary system for installing laminate floors without using glue.
Recommended for most areas position the plank to be installed at an angle of 20 to 30 to the plank already installed.
Remove any obstacles and provide sufficient ventilation minimum 4cm 1 1 2 of total ventilation holes per meter 40 of floor.
Naturetek instructions naturetek select instructions naturetek plus instructions.
In rows where there is a pipe make sure the pipe falls exactly in line with the short side of two panels.