The stair tread depth shall be measured horizontally between the vertical planes of the foremost projection of adjacent treads and at right angle to the tread s leading edge.
Stair tread nosing depth.
For stair treads less than 9 inches deep secure a new deeper tread directly on top of the existing tread.
Styles a and b are for use on wood or concrete stairs.
A nosing is not required where the tread depth is a minimum of 11 inches 279 mm.
11 280 mm min.
The surewood lnl 13 in.
Stair tread nose curve radius 9 16 or 1 2 in some codes.
The stair tread depth red arrow is measured from the forward edge of the step nose or edge of the step above out to the leading edge of the step being measured.
Screw nosing into place to protect the front portion of the stair and provide a slip resistant surface.
A nosing is not required where the tread depth is a minimum of 11 inches 279 mm.
So since the minimum tread size is 10 a nosing will extend the tread depth to between 10 3 4 and 11 1 4.
Beveling of nosings shall not exceed 1 2 inch 12 7 mm.
Staircase tread run depth.
For concrete stairs use concrete anchors with 4 screws.
Unfinished red oak tread nosed return is made for interior stair construction from attractive natural oak.
Treads and risers 1 except as permitted for dwelling unitsand by sentence 3 4 7 5 1 for fire escapes steps for stairs shall have a run of not less than 255 mm and not more than 355 mm between successive steps.
Attaches to the ends of plain treads to create a return tread in open stringer stair designs.
10 to 11 inches minimum.
Construction adhesive sold separately is for use between nosing and the front edge of the stair to prevent cracks.
For wood stairs use 4 wood screws.
7 180 mm max.
Unfinished red oak tread the surewood lnl 13 in.
The stair riser must measure 8 to 8 1 4 inches high.
2 steps for stairs referred to in sentence 1 shall have a rise between successive treads not less than 125 mm and not more.
A step tread is the flat horizontal surface that you walk on.
Stair tread depths shall be 11 inches 279 mm minimum.
5 13 mm max.
The ontario building code treads and risers 3 4 6 8.
The greatest stair tread nosing projection shall not exceed the smallest nosing projection by more than 3 8 inch 9 5 mm between two stories including the nosing at the level of floors and landings.
It is sold unfinished allowing you to finish it to match other red oak stair parts or decor.
For a typical staircase the stair tread must measure 8 1 4 inches to 9 inches deep measure 1 inch thick or more and have a maximum 1 1 2 inch deep nosing.
4 100 mm min.